Trenches behind small wastewater treatment systems
Required wall area (m2/inhabitant value PE):
1 m2 / PE to 1.5 m2 / PE with: Sand-gravel mixture, sand, light silty sand
2 m2 / PE to 2.5 m2 / PE with: Silt (also light clay), sand-silt mixture, stone-loam mixture
Required number for example of DRAINMAX Tunnel:
Base element 2.25 m length x 0.8 m heigth x 2 sides
As = 3.6 m2 per tunnel without front walls
PE to 1.5 m²/PE to 2.5 m²/PE
4 1 pcs. 2 pcs.
8 1 pcs. 4 pcs.
12 3 pcs. 6 pcs.
16 4 pcs. 8 pcs.

A specified calculation must be done with other soil conditions and higher PE values.