Translations:Wasseraufbereitung und Grauwassernutzung/948/en: Unterschied zwischen den Versionen
Aus INTEWA Wiki
(Die Seite wurde neu angelegt: „====Chemical cleaning==== The AQUALOOP membrane can be loaded with 1 Mio. ppm free chlorine without limitation on its 10-year lifespan. With the recommended cl…“) |
|||
Zeile 1: | Zeile 1: | ||
− | ==== | + | ====Flow rate and membrane life with chemical cleaning==== |
The AQUALOOP membrane can be loaded with 1 Mio. ppm free chlorine without limitation on its 10-year lifespan. With the recommended cleaning concentration of 0.25% (= 2500 ppm) approx. 400 chemical cleanings can be conducted without limiting the lifespan. To calculate a reduced lifespan due to chlorine cleaning, the following formula can be used: | The AQUALOOP membrane can be loaded with 1 Mio. ppm free chlorine without limitation on its 10-year lifespan. With the recommended cleaning concentration of 0.25% (= 2500 ppm) approx. 400 chemical cleanings can be conducted without limiting the lifespan. To calculate a reduced lifespan due to chlorine cleaning, the following formula can be used: |
Aktuelle Version vom 21. Februar 2019, 13:29 Uhr
Flow rate and membrane life with chemical cleaning
The AQUALOOP membrane can be loaded with 1 Mio. ppm free chlorine without limitation on its 10-year lifespan. With the recommended cleaning concentration of 0.25% (= 2500 ppm) approx. 400 chemical cleanings can be conducted without limiting the lifespan. To calculate a reduced lifespan due to chlorine cleaning, the following formula can be used: